Descriptions
Alat ukur ketebalan lapisan seperti cat, epoxy, kertas, plastik dan lain-lain dengan range tidak melebihi 1.25 cm.
Feature
- TT220: integrated probe F, Measuring method: magnetic induction
- TT230: integrated probe N, Measuring method: eddy current
- 2 measurement modes: continuous / single
- 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
- 15 measurement readings stored
- Low battery indication
- Automatically switch off
- Real time or batch printing
Specifications
- Probe Types :N
- Measuring methods : eddy current
- Measuring range : 0-1250µm
- Tolerance :
- I point calibration: + (3%H+1.5)
- 2point calibration + ((1-3)%H+1.5)
- Measuring condition:
- Min culvalute :convexity 3
- Min. Testing area ¢5
- Critcal thickness of substate (mm): 0.3