Untuk memesan, silahkan tekan tombol ORDER. Anda bisa memesan barang secara Online.
DESCRIPTION
Trainer for controller tuning. This unit
permits the interaction between controller and controlled system. The
objective is that the closed control loop, formed by the controller and
the controlled system, to show the desired optimum response. With a
simulation software the setting of controller parameters can be
practised safely. Closed an open loop control, step response, stability,
disturbance and control response are demonstrated. This trainer no
needs real controlled systems, the controlled system is simulated on a
computer (PC) by the simulation program. In this program the most
important types of controlled systems can be selected . We can recorder
and analyse the time response using the software. The process controller
used can be easily configured from the computer (PC) across an
interface using the configuration software. The controller and the
computer (PC) are connected by a data acquisition card with AD and DA
converters.
The trainer basically is formed by:
The trainer basically is formed by:
- Digital process controller, configurable as a P, PI or PID controller, with interface.
- Interface for computer (PC).
- Data acquisition card for computer (PC).
- Simulation software for different controlled system types.
- Configuration software for the controller.
SPECIFICATION
Trainer for controller tuning.
Steel box.
Configurable digital process controller, with interface:
Configurable as P, PI or PID controller. Proportional gain X : 0-999.9%. Integral action time T : 0-3600s. Derivative time T : 0- p n v
1200s.
Interface for computer (PC).
Data acquisition card for computer (PC).
Simulation Software for controlled system models, such as 1st and 2nd order lags, time-delayed systems etc. Controlled system
simulation models with proportional, integral, 1st order lag, 2nd order lag, time-delayed response, non-linearity and limitation.
Configuration software for process controller.
Recording and evaluation of time response on computer (PC).
Process variables as analog signals: 0-10V.
Set of cables.
Manuals:
This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals.
Steel box.
Configurable digital process controller, with interface:
Configurable as P, PI or PID controller. Proportional gain X : 0-999.9%. Integral action time T : 0-3600s. Derivative time T : 0- p n v
1200s.
Interface for computer (PC).
Data acquisition card for computer (PC).
Simulation Software for controlled system models, such as 1st and 2nd order lags, time-delayed systems etc. Controlled system
simulation models with proportional, integral, 1st order lag, 2nd order lag, time-delayed response, non-linearity and limitation.
Configuration software for process controller.
Recording and evaluation of time response on computer (PC).
Process variables as analog signals: 0-10V.
Set of cables.
Manuals:
This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals.