Senin, 16 Februari 2015

Reactive Power Compensation (Power Factor Correction)

Untuk memesan, silahkan tekan tombol ORDER. Anda bisa memesan barang secara Online.
 
Anda juga bisa memesan via telephone, silakan hubungi sales consultant. Hotline kami di (021) 8690 6777 sales Consultant kami akan menjelaskan detail produk dan harga terbaru. atau email ke alamat sales@alatperaga.com







This application includes:
AI8 unit, in metallic box, including:
  • Three-phase AC power supply:
  • Neutral (black) + R phase (red) + S phase (yellow) + T phase (green)
  • connectors.
  • Magneto-thermal protection.
  • Differential protecion.
  • Mushroom security button.
  • ON/OFF contact by removable key.
Variable resistive load (variable resistance), 500 W, variable up to 150 by a rheostat.
Two coils with inductive loads of 33, 78, 140, 193 and 236 mH, each one.
Three banks of of 4 capacitors of 7 ΩF, each one. Ground connection.
Protection fuses (3.15A).
EAL. Network Analyzer Unit.
  • Cables and Accessories, for normal operation.
  • Manuals: This application is supplied with the following manuals: Required Services,
  • Assembly and Installation, Starting-up, Safety, Maintenance Practices
  • Manuals.
  • This unit shows the main electric parameters on the electric network through the
  • interface and an parameter selection.
  • Metallic box.
  • Diagram in the front panel.
  • 3 current inputs, for series intensity.
  • 3 voltage terminals, for each phase (R,S,T) measure and another one for the connection.
  • Control and visualization digital display.
  • Voltage: Range 20 - 500 Vrms. Prec.: 0.5%. Phase to phase - Phase to neutral.
  • Current: Range 0.02 - 5 Arms. Prec.: 0.5%.
  • Frequency: Range 48 to 62 Hz. 0.1Hz.
  • Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: 1%.
  • Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1.
  • Prec.: 1%.
  • Operating temperature 0 to +50°C.
EXERCISES AND PRACTICAL POSSIBILITIES
1.- Measurement of active power consumed by a receiver (resistive circuit).
2.- Measurement of the inductance of a coil.
3.- Measurement of the reactance XL considering RL.
4.- Measurement of reactive power consumed by a receiver  (inductive circuit).
5.- Measurement of reactive power consumed by a receiver (capacitive circuit).
6.- Measurement of apparent power consumed by a receiver.
7.- Measurement of power factor of a receiver.
8.- Measurement of active energy consumed by a receiver.
9.- Measurement of reactive energy consumed by a receiver.
10.-Compensation of reactive energy (improvement of the power factor).
11.-Comparison of the active energy consumed after the compensation.
12.-Comparison of the reactive energy consumed after the compensation.
13.-Measurement of power factor after the compensation.

0 komentar:

Posting Komentar

 

Labels

About Us

ALAT PERAGA Copyright © 2009 Community is Designed by Sacha Blogger Template

CSS done by Link building